ALSA: hda/tas2781: Accept V1 calibration data without CRC
Some Lenovo BIOSes (e.g. Legion Pro 7 16IRX9H, SSID 17aa:38cd) store valid V1 calibration data in the CALI_DATA EFI variable but leave the TimeStamp and CRC fields zeroed. The driver rejects such data, so the amplifiers always run with default parameters on these machines. The rejection was silent until commit 4fe238513407 ("ALSA: hda/tas2781: Move and unified the calibrated-data getting function for SPI and I2C into the tas2781_hda lib") turned it into "V1 CRC error". The stored values are consistent (R0 = 3.82/3.83 ohm, 1/R0 matching within 1e-4), so accept V1 data when both TimeStamp and CRC are zero and the first device entry is non-zero, and emit a warning. Fixes: 5be27f1e3ec9 ("ALSA: hda/tas2781: Add tas2781 HDA driver") Cc: stable@vger.kernel.org Signed-off-by: Mohamed Yassine Jebabli <med.jebabli@gmail.com> Link: https://patch.msgid.link/20261001-tas2781-v1-nocrc-v1-1-ff0c1032ce76@gmail.com Signed-off-by: Takashi Iwai <tiwai@suse.de>